VMAT is modular expandable, composing multiple i-36 vibrating membrane units with single PLC control
| Industrial Unit | One i-36" vibrating membrane unit |
| Membrane area | 40 sq. meter |
| Daily treatment capacity | 8 m3 feed |
| Feed source | Used motor oil or similar lubricants |
| Filtration temperature | 80-90°C |
| Filtration pressure | 3–5 kg/cm2 |
| Power requirement | 380 VAC 3-phase, 5 cores, 50/60 Hz, 150A supply, 45A in operation |
| Power consumption | 33KW |
| Heating energy consumption | 37MJ per hour (starting temperature from 30°C) |
| Working environment | Indoor or sheltered area against direct sun light or rainfall |
| Area (excluding storage) | App. 350 sq. meter |
| Ambient temperature | 5-37°C |
| Storage temperature | 2-70°C |
| Filter pack life | Warranty one year |